Product comparison

Aidlab 2 vs Equivital EQ02+ LifeMonitor

Equivital EQ02+ is a certified medical chest monitor with 2-lead ECG and optional core temperature. Aidlab 2 adds faster ECG sampling, EDA, GNSS, and public SDKs to a smaller module.

Man hiking with Aidlab 2 on an electrode chest strap

At a glance

What each manufacturer documents for these models.

Aidlab 2 vs Equivital EQ02+ LifeMonitor: signals at a glance
SignalAidlab 2Equivital EQ02+ LifeMonitor
ECG1-lead, 250 Hz, configurable up to 1000 Hz2-lead, 256 Hz
RespirationImpedance waveform, 50 HzWaveform, 25.6 Hz
Skin temperatureYesInfrared, every 15 s
Core temperatureNot listedWith a compatible capsule
EDABuilt inWith a wired GSR sensor
Motion9-axis3-axis acceleration
GNSSYesNot listed
Onboard memory4, 8, or 32 GB8 GB
BatteryUp to 24 hours48 hours, 150 with an external pack
SDKsPython, Android, Apple, Flutter, UnityAndroid, .NET, Java
Medical deviceNot listedFDA Class II, CE Class IIb
List priceFrom $729Not listed
Compared model

Equivital EQ02+ LifeMonitor

Sensor belt with a docked Sensor Electronics Module

  • 2-lead ECG at 256 Hz, breathing at 25.6 Hz, and 3-axis acceleration at up to 256 Hz [8]
  • Infrared skin temperature, plus core temperature through a compatible ingestible capsule [7][8]
  • 8 GB of memory, FDA Class II and CE Class IIb, with SDKs for Android, .NET, and Java [8][9]
View official Equivital EQ02+ LifeMonitor documentation
Editorial interpretation

The 30-second verdict

This decision guide is Aidlab's interpretation of the documented capabilities below.

Choose Aidlab 2 if

  • ECG at 500 or 1000 Hz matters for your analysis.
  • EDA and GNSS belong in the same recording.
  • You want a public SDK for Python, mobile, Flutter, or Unity.

Choose Equivital EQ02+ LifeMonitor if

  • The protocol needs two ECG leads or core body temperature.
  • Participants work in heat, water, or hazardous environments.
  • The study requires FDA Class II or CE Class IIb status.

Decision boundary

Equivital is a certified field monitor with core temperature. Aidlab 2 trades that for higher ECG sampling, more onboard sensors, and an open developer path.

Documented capabilities

Signals, sampling, and access

The rows compare what each manufacturer publishes for these models. Equivital figures come from its EQ02+ datasheet.

Aidlab 2 vs Equivital EQ02+ LifeMonitor: documented product capabilities
CriterionAidlab 2Equivital EQ02+ LifeMonitorEditorial interpretation
ECG1-lead ECG at 250 Hz by default, configurable to 500 or 1000 Hz2-lead ECG at 256 Hz, 10-bit

Equivital records two leads; Aidlab 2 samples one lead up to four times faster.

Sources:[4][6][8]

RespirationChest-impedance waveform at 50 Hz and respiration rateBreathing waveform at 25.6 Hz and breathing rate

Both record a breathing waveform from the chest.

Sources:[4][8]

TemperatureSkin temperature with 0.01°C resolutionInfrared skin temperature, plus core temperature through a compatible capsule

For heat-stress and occupational studies, core temperature favors Equivital.

Sources:[4][7][8]

Other sensingBuilt-in EDA, 9-axis motion, GNSS, and sound level3-axis acceleration and body position; GSR and SpO2 through separate sensors

Aidlab 2 builds more sensors into the module.

Sources:[1][4][7][8]

SoftwarePublic SDKs for Python, Android, Apple platforms, Flutter, and UnityEquivital Manager, eqView, and Qiosk, plus SDKs for Android, .NET, and Java

Equivital includes ready research software; the Aidlab SDK adds Python and Apple platforms.

Sources:[3][9][10]

Hardware and regulatory statusResearch and development wearable, up to 24 hours per chargeFDA Class II and CE Class IIb, 48 hours per charge, and an explosive-environment version

Equivital wins on certification, battery life, and ruggedness.

Sources:[1][7][8]

ECG

Aidlab 2

1-lead ECG at 250 Hz by default, configurable to 500 or 1000 Hz

Equivital EQ02+ LifeMonitor

2-lead ECG at 256 Hz, 10-bit

Editorial interpretation

Equivital records two leads; Aidlab 2 samples one lead up to four times faster.

Sources:[4][6][8]

Respiration

Aidlab 2

Chest-impedance waveform at 50 Hz and respiration rate

Equivital EQ02+ LifeMonitor

Breathing waveform at 25.6 Hz and breathing rate

Editorial interpretation

Both record a breathing waveform from the chest.

Sources:[4][8]

Temperature

Aidlab 2

Skin temperature with 0.01°C resolution

Equivital EQ02+ LifeMonitor

Infrared skin temperature, plus core temperature through a compatible capsule

Editorial interpretation

For heat-stress and occupational studies, core temperature favors Equivital.

Sources:[4][7][8]

Other sensing

Aidlab 2

Built-in EDA, 9-axis motion, GNSS, and sound level

Equivital EQ02+ LifeMonitor

3-axis acceleration and body position; GSR and SpO2 through separate sensors

Editorial interpretation

Aidlab 2 builds more sensors into the module.

Sources:[1][4][7][8]

Software

Aidlab 2

Public SDKs for Python, Android, Apple platforms, Flutter, and Unity

Equivital EQ02+ LifeMonitor

Equivital Manager, eqView, and Qiosk, plus SDKs for Android, .NET, and Java

Editorial interpretation

Equivital includes ready research software; the Aidlab SDK adds Python and Apple platforms.

Sources:[3][9][10]

Hardware and regulatory status

Aidlab 2

Research and development wearable, up to 24 hours per charge

Equivital EQ02+ LifeMonitor

FDA Class II and CE Class IIb, 48 hours per charge, and an explosive-environment version

Editorial interpretation

Equivital wins on certification, battery life, and ruggedness.

Sources:[1][7][8]

Equivital lists GSR and SpO2 through separate compatible sensors. Its own pages state 40 or 50 days of logging and IP67 or IPx7; this page uses the datasheet.

Detailed view of the Aidlab 2 chest-worn sensor module
Wear → record → integrate

Two chest systems for work outside the lab

Both record away from a phone. They differ in what they measure without accessories and how you reach the data.

1 · Wear

Aidlab 2

Clip the module onto a compatible electrode chest strap.

Equivital EQ02+ LifeMonitor

Choose one of nine belt sizes and dock the Sensor Electronics Module on the left side.

Equivital needs a sized belt per participant; Aidlab 2 uses one strap.

2 · Record

Aidlab 2

ECG, respiration, EDA, skin temperature, 9-axis motion, and GNSS from one module.

Equivital EQ02+ LifeMonitor

2-lead ECG, breathing, skin temperature, and acceleration, with core temperature and GSR through accessories.

Equivital adds core temperature; Aidlab 2 builds EDA and GNSS into the module.

3 · Integrate

Aidlab 2

Public SDKs for Python, Android, Apple platforms, Flutter, and Unity.

Equivital EQ02+ LifeMonitor

Equivital Manager for CSV export, eqView and Qiosk software, and SDKs for Android, .NET, and Java.

Equivital includes ready research software; Aidlab 2 covers more programming languages.

Questions buyers ask

Frequently asked questions

What is the Equivital EQ02+ ECG sampling rate?

The EQ02+ datasheet lists 2-lead ECG at 256 Hz with 10-bit resolution. Aidlab 2 records 1-lead ECG at 250 Hz by default and can be configured to 500 or 1000 Hz.

Which languages do the Equivital and Aidlab SDKs support?

Equivital lists SDK products for Android, .NET, and Java. The Aidlab SDK is available for Python, Android, Apple platforms, Flutter, and Unity.

When is Equivital EQ02+ the better choice?

When the protocol needs two ECG leads, core body temperature, rugged or explosion-safe hardware, or a device with FDA Class II and CE Class IIb status.
Sources

Official documentation used

Every capability above links to the manufacturer documentation used.

Last reviewed

  1. Aidlab 2 product page

    Official model-specific signals, form factor, intended use, and availability.

  2. Aidlab SDK: data types and events

    Official signal definitions, units, storage behavior, and SDK callbacks.

  3. Aidlab SDK documentation

    Official integration documentation for supported platforms.

  4. Aidlab 2 support: measurement range and accuracy

    Official Aidlab 2 sampling rates, resolution, and measurement ranges.

  5. Aidlab 2 support: storage

    Official Aidlab 2 memory variants and recording without a phone.

  6. Aidlab SDK: configuration

    Official ECG sampling-frequency options and their effect on other signals.

  7. Equivital EQ02+ LifeMonitor product page

    Official product overview, accessories, and regulatory statement.

  8. Equivital EQ02+ LifeMonitor datasheet

    Official ECG, breathing, temperature, accelerometer, memory, battery, and classification specifications.

  9. Equivital Training and Research brochure

    Official software and SDK products, belt sizes, and accessories.

  10. Equivital research software

    Official Equivital Manager, eqView, and Qiosk descriptions.

Caveats

  • No controlled accuracy or comfort study between Aidlab 2 and Equivital EQ02+ was performed for this page.
  • Aidlab 2 is a research and development wearable, not a medical device.
  • Equivital does not publish prices for EQ02+ or its SDKs.
Next step

Review the documented requirements with your protocol

Compare the required signals, recording mode, connectivity, and data path before choosing a device.